INTRODUCTION
This is the accompanying background info for the simple version of the setup-process that is integrated into Svalbard Audio's KLAR (click here for the advanced version). The setup helps you integrate one or two subwoofers with your main monitors, and guides you through the calibration of your monitoring system's low-end.
The simple version of the setup might actually be all you need to get a neutral, calibrated monitoring system. If the final measurements at the end of the setup reveal any issues that need closer inspection, you can dive deeper with the advanced setup that gives you more options for detailed fine-tuning.
Room EQ Wizard (REW) will be used for the analysis of the measurements you make in KLAR. But you don't need any REW experience to successfully complete the setup process, cause you will be guided through each step in both KLAR and REW.
KLAR is available as a VST/AU plugin or as a standalone application. The standalone version is normally the preferred option, as it can be be used without opening your DAW, when your DAW is exporting/loading and without any setup/routing in your DAW. The only minor downside is the small amount (two buffers) of additional latency it introduces, compared to the latency-free plugin version. So if you really need super low latency, you can load KLAR as a plugin (several communicating ones actually) on each output you want to use, and load the settings you created in the standalone version.
Equipment needed:
Software :
- Svalbard Audio KLAR.
- Room EQ Wizard.
Hardware:
- (Measurement) microphone (a mic stand is recommended). More info on selecting a suitable microphone.
- Subwoofer.
- Studio monitors.
- Audio interface with separate outputs for monitors and subwoofer.
- Cables to connect it all.
- Computer with macOS or Windows.
1.
Install REW
- Download the latest Beta version* that's available from avnirvana.com. Depending on which OS you use and which exact REW version you installed, the screenshots on this site might look slightly different, but it should function the same.
- Install REW with the default options.
* The current regular download (version 5.20.13) directly from roomeqwizard.com crashes has issues when importing sweep recordings, so please use the beta version for now.
2.
Install KLAR
Windows
a. Download the Windows installer (.exe) from svalbardaudio.com and install KLAR.
b. Click 'Run anyway' if Windows Defender shows a 'Windows protected your PC' message and follow the steps in the installer.
macOS
a. Download the macOS installer (.pkg) from svalbardaudio.com and install KLAR
b. Enter your password and follow the steps in the installer.
1.
Connect monitors & subwoofer(s) to individual outputs:
Before you can start the actual setup process you should make sure all your hardware is properly connected & set up. To be able to control your sub(s) and monitors independently, they all need to be connected to separate outputs on your interface. This way KLAR can process all outputs individually, whether running standalone or as a plugin in your DAW- Make sure you only connect the monitors to the hardware controller, not the sub.
- Make sure to either bypass the controller (if possible) or set it to a fixed, repeatable level when using KLAR.
- Beware of any signal degradation caused by the hardware controller. A direct connection from interface to speakers will almost always sound better.
2.
Connect a microphone
Select a suitable measurement microphone and connect it to a microphone preamp on your audio interface. Make sure the cable is long enough to reach your monitors & sub.3.
Disable all available processing features on your subwoofer
- Polarity : '0 'or 'OFF'.
- Phase: '0 'or 'OFF'.
- Lowpass (cutoff, crossover) frequency: highest frequency available or bypass.
- EQ/contour: '0'or 'OFF'
- DSP: bypass as many settings as possible.
- Bass management: 'OFF'
- Low cut: '0' or 'OFF'
- Set the volume/gain/output level to its maximum settings.
- Settings related to satellite/highpass are not relevant since the monitors will not be connected to the sub.
4.
Adjust these settings (if available) on your monitors
- EQ/Frequency controls (bass/treble/high/contour): '0, 'OFF' or 'Bypass'.
- DIsable room compensation/boundary correction/acoustic space EQ by setting: '0 ', 'OFF' , 'WHOLE/FULL SPACE' or 'FREE FIELD', depending on the make & model.
- DSP: bypass as many settings as possible.
- Set the volume/gain/output level to it's maximum settings (this might change in a later step).
- High pass: 'OFF' or 'Bypass'.
5.
Enable loopback
- Route an actual cable from a physical output (this will be called the loopback output) to a physical input (which we'll call the loopback input). Simple as that. A cable that sends all audio that goes out of your interface directly back in. Make sure the mixer of your audio interface doesn't send this input to the corresponding output, to avoid feedback. A digital input/output would be the best option, cause it will, for example, enable bit-accurate recording of reference tracks in your DAW, but an analog input/output would work fine too.
- Use your audio interface's loopback functionality. If available (check the manual) there's either a dedicated loopback input available (eg with Focusrite), or an output of your interface can be selected as the loopback output (eg with RME) and the corresponding input will turn into a loopback input. So if you enable loopback on output 8, input 8 will receive all audio that you send to output 8 (as if a cable was connected from output to input).
- Software loopback. There are several software loopback drivers available. In the software you want to play from you set this driver as the output. in KLAR as the input.On macOS a good option is: Blackhole.On Windows I have not found a reliable solution yet.
If you're using software loopback, you should select this as an input later. For now you need your audio interface as the input device, cause your measurement microphone is connected to it.
Gain staging
Roll-off measurement
The roll-off measurement is used to determine the current roll-off. Once you've analysed it in the next step, a filter will be applied automatically to 'flatten' the roll-off so it won't interfere with KLAR's crossover. if you want to know more about this you can read the info on shelving filters that is included in the advanced setup procedure.
Fixing Polarity issues
If KLAR warns you that the polarity of one of your monitors or subs appears to reversed, try to find the cause of the reversal by changing potential causes one by one, and remeasuring after each change:
- Check to see if you your monitor or sub has a polarity switch that's accidentally engaged.
- Try a different cable.
- Check if the software of your audio interface has a polarity button on the corresponding output channel.
- Polarity switches are sometimes labelled 'Phase'.
Importing measurements
Importing measurements
General instructions for importing sweep measurements in REW:
- In KLAR, click the 'Open folder' button to open the folder on your harddrive containing the measurements.
- Open REW and choose File > Import > Import Sweep Recordings. Check the Apply cal files box if you've got a calibration file that was made for your specific measurement microphone. Make sure the right calibration file is loaded in REW by going to REW > Preferences > Cal Files > Mic cal files > the one with the pink lettering above it is the one that will be used for the imports. Use the regular version (sometimes a 90 degrees version is also supplied).
- Where it says Stimulus, drag in the file called 'REW Stimulus.wav' that's also in the folder that just opened.
- Go back to the folder containing the measurements that KLAR opened in step 1.
- Simultaneously drag & drop all files you want to analyse (in one go) from the folder to the Response area in the lower square in the REW window. You don't need to use the 'Browse' button.
- Close the 'Import Sweep' window.
- All imported measurements will have been added to the column on the left.
Calculate phase in REW
- Click 'Open folder' and import the '... - phase' sweep measurements in REW (see 'Import sweep measurements' for instructions).
- Click the 'All SPL' tab.
- Click the '10...200' button in the bottom right corner.
Alignment procedure
- Click 'Controls' (in the top right corner) and then click 'Alignment tool'.
- In the drop-down menus at the left, select 'Subwoofer - phase' for the top one and 'Monitor - phase' for the bottom one.
- Click in the ' All SPL' frequency graph so the 'cross-sign' & corresponding vertical line are placed at approx 85Hz (may deviate a few decimals). The horizontal part of the line is not relevant.
- Click 'Align Phase at Cursor' to calculate the delay for the phase to match at the frequency the cursor is placed.
- The overlayed frequency response curve shows the predicted response with this delay setting. You can also try selecting the 'Invert polarity' box (within the alignment tool window) of the subwoofer, to find out if this leads to a flatter curve and/or a smaller delay value.
- Click 'Aligned sum' to create a new simulated measurement with the delay & polarity values added in the notes section.
- Click 'Controls' (in the top right corner) and then click 'Alignment tool'.
- In the drop-down menus at the left, select 'Subwoofer 1 - phase' for the top one and 'Subwoofer 2 - phase' for the bottom one.
- Click in the ' All SPL' frequency graph so the 'cross-sign' & corresponding vertical line are placed at approx 85Hz (may deviate a few decimals). The horizontal part of the line is not relevant.
- Click 'Align Phase at Cursor' to calculate the delay for the phase to match at the frequency the cursor is placed.
- The overlayed frequency response curve shows the predicted response with this delay setting. You can also try selecting the 'Invert polarity' box (within the alignment tool window) of subwoofer 2, to find out if this leads to a flatter curve and/or a smaller delay value. You can also try if setting the vertical line to a lower frequency (eg 50Hz instead of 85Hz) leads to a better result.
- Click 'Aligned Sum' (bottom right corner) and rename the new simulated measurement that appears at the left to 'Subwoofer - phase'.
Create filters for complete system low-end correction
Import the five low-end measurements in REW and create correction filters using the step in this video and/or the text below:
Import the measurements:
- Click 'Open folder'.
- Import the five 'Combined low-end' measurements in REW.
- Click the 'All SPL' tab (2nd on top row)
- Select only the 5 measurements you just imported (using the checkbox at the bottom).
- Click 'Controls' (top right corner).
- Click 'Align IR start'.
- Click 'Vector Average'.
- Check if the level of the 'vector average' measurement that got added lies in between the level of the five source measurements. Otherwise redo the measurements.
- Rename the newly created measurement to 'Combined low-end average.
- Click the 'SPL & Phase' tab (1st on top row)
Create correction filters:
-
Click the 'EQ' icon in the top area.
-
Click the 10-200 button in the bottom right corner.
-
Go to 'Target Settings' and set 'Target Type' to 'Speaker driver' (leave all settings at 'none').
-
Adjust 'Target level' so the blue target line sits roughly around the average level of the 10-200Hz range.
-
Go to the 'Filter Tasks' tab (directly below where you are now) and make it look like this. You can also try set the flatness target to 2dB if REW creates more than 10 filters:
- Click 'Match response to target'. Click 'OK' if a warning popups up about the level being too low.
- Click 'EQ filters' on the top to edit the filters if you feel the response could be smoother. Filters below 30Hz with gains larger than -20dB should always be removed, cause these are probably cause by background noise. If you spot filters that boost & cut at nearly the same frequency (within a few Hz) you should remove those too.
- Once you're happy with the way the predicted curve looks, go to:
- Go to 'Filter tasks'
- Click 'Export filter settings as text' (bottom right corner)
- Click 'ok' in the 'filter settings notes' popup.
- Use a descriptive filename (e.g. 'Complete correction low-end'),
- Pick a convenient location to save the file, and hit 'Save'. - Go back to KLAR, click next, and import the file.
Import & analyse the final system
Import the low-end sweep measurements:
- Click 'Open folder' and import the five 'Final low-end ..' measurements in REW (see 'Import sweep measurements' for instructions).
- Go to the 'All SPL' tab and click 10...200 in the bottom right corner to zoom in on the frequency range of interest.
- Select the 5 remaining 'Final low-end..' measurements.
- Compare the five measurements visually to identify the peaks and dips that are more or less common to all of them. If one or two of your five responses seem really different from the rest of them, you can choose to deselect those. If you choose to ignore a certain area previously, ignore it now as well.
- Click the ''Controls' (top right corner) and click the 'Vector Average' button.
- Rename the newly created files to 'Final low-end average' in the column on the left.
- Delete the five original measurements you've just created the average from.
Backup & Save
- In REW go to File > Save all measurements and choose a location (preferably the same location you used to backup the KLAR measurements in 8f) to save all REW measurements for future reference.
- Go back to KLAR, click File > Save As and choose a convenient file name for the current KLAR file.
- Click 'Show KLAR' to show KLAR's main screen
Adjustments to taste - target curve
Decades of blind listening test have shown that listeners prefer a flat on-axis (the direct sound coming from your monitors) response. But depending on your personal preference, listening levels and the reflectiveness of your room combined with the way your speakers radiate sound into the room (directivity) a low shelf to boost the boost low frequencies and/or a slight tilt of the complete frequency range might sound best to you. Some amount of low-shelfing is almost always preferred, so this is implemented in the target curve that's activated by default. Try listening to some reference tracks you know well and try to judge whether the overall impression is too bright and/or bass-shy, and gradually adjust the target curve EQ setting accordingly. Try to listen at the volume you normally work at. How to change the target curve in KLAR:- In KLAR go to the 'Monitor editor' (click the icon directly right to the 'MON + SUB' preset).
- Click on the Target Curve default' EQ node.
- The 'Target curve default' preset gets activated when you switch to the main screen for the first time, it is not active during measurement. You try out different presets by clicking on the arrow to the right of the 'Target curve default' name and/or you can change the eq settings manually.
- To easily compare different settings you can create or duplicate presets by using the bottom right icon to go to the 'Preset manager' screen.
- Compare different 'house curve' EQ settings
- With or without room correction for mid and/or high frequencies.
- Different settings for different locations
- Different crossover points (might have to change room correction)
- Mix tools > mono > Swap left & right channels > Limited frequency range ('the flat auratone') > Smile curve ('edge case EQ')